Difference between revisions of "16CH Binary Input"

From KONNEKTING Wiki
Jump to navigation Jump to search
Line 39: Line 39:
  
 
== Hardware ==
 
== Hardware ==
 +
'''What you need:'''
 +
for this device do you need:
 +
* 1x OKW Housing
 +
* 1x PCB Kit
 +
* 1x Mounting Kit (screws, ...)
 +
 +
'''OKW Housing''' link OKW-Website:[https://www.okw.com/de/category/813fb100-6960-11e5-b123-8eba63e66ed5/products?vs=c9f11140-cb2e-11e3-89f9-00163e72470b%24%24f3236741-633f-11e3-937d-00163e72470b]
 +
1x B6503121 RAILTEC B, 4 Module
 +
3x B6607140 Klemmenabdeckung, flach
 +
1x B6607145 Abdeckung KNX, flach
 +
4x B6607142 Klemmenabdeckung, flach
 +
(1x) B6603180 Frontplatte, 4 Module (only if you don't use the "LED-Status-PCB"
 +
 +
 +
'''PCB Kit:'''
 +
1) Application PCB
 +
2) Controller PCB
 +
3) LED-Status PCB (for function not necessary, only to show the status of the Inputs)
 +
4) Mini-BCU (KNX-Transceiver)
 +
[[File:16CH_Binary_Input_PCBs.jpg|390px]]
 +
 +
 +
'''Mounting Kit'''
 +
4x
 +
 +
 
{| class="wikitable" style="text-align:center"
 
{| class="wikitable" style="text-align:center"
 
| [[File:16CH Binary Input PCB Stacked.jpg|450px|thumb|without housing]]
 
| [[File:16CH Binary Input PCB Stacked.jpg|450px|thumb|without housing]]
| [[File:16CH_Binary_Input_PCBs.jpg|390px|thumb|PCB overview]]
 
 
|}
 
|}
  

Revision as of 14:12, 21 February 2018

16CH Binary Input
16CH Binary Input Overview.jpg
16CH Binary Input comp.jpg
Developer Matthias F.
Status Version 1.0 finished
Microcontroller/Board
KNX connectivity Mini-BCU


Description

16ch Binary Input (potential-free)

The binary input has 16 inputs available and is used to connect eight conventional push-buttons or floating contacts such as window or relay contacts. There is one status LED for each input. In addition, the input status is sent to the bus. A separate power supply is not necessary


Technical Data:

  • 16 Inputs (potential-free / floating contacts)
  • wire length tested 30m (more possible)
  • x-Inputs can configure to a "room" ("room"-GA can show if one of the windows is open in the room)
  • Counting of pulses, suitable for 30ms S0 pulses (CH13 -CH16 can use for S0)
  • The device makes a contact supply voltage (5V) which is not electrically isolated from the bus voltage!

Schematic

16CH Binary Input Schematic.png


Hardware

What you need: for this device do you need:

  • 1x OKW Housing
  • 1x PCB Kit
  • 1x Mounting Kit (screws, ...)
OKW Housing link OKW-Website:[1]
1x B6503121 RAILTEC B, 4 Module
3x B6607140 Klemmenabdeckung, flach 
1x B6607145 Abdeckung KNX, flach
4x B6607142 Klemmenabdeckung, flach 
(1x) B6603180 Frontplatte, 4 Module (only if you don't use the "LED-Status-PCB" 


PCB Kit:
1) Application PCB
2) Controller PCB
3) LED-Status PCB (for function not necessary, only to show the status of the Inputs)
4) Mini-BCU (KNX-Transceiver)
16CH Binary Input PCBs.jpg


Mounting Kit
4x 


without housing

Software

User Documentation

16Ch Input
12Ch Input + 4Ch S0-Interface

Developer Documentation

Build It

Links